miniflux/v2 · Security
Miniflux has an Open Redirect via protocol-relative redirect_url
- GHSA ID
- GHSA-wqv2-4wpg-8hc9
- CVE ID
- CVE-2025-67713
- Severity
- medium
- Published
- Updated
- CVSS v4
- 5.3 · CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N
Description
Summary
redirect_url is treated as safe when url.Parse(...).IsAbs() is false. Protocol-relative URLs like //ikotaslabs.com have an empty scheme and pass that check, allowing post-login redirects to attacker-controlled sites.
Details
url.Parse("//ikotaslabs.com")=> empty Scheme, Host="ikotaslabs.com".IsAbs()returns false for//ikotaslabs.com, so the code treats it as allowed.- Browser resolves
//ikotaslabs.comto current-origin scheme (e.g.https://ikotaslabs.com), enabling phishing flows after login.
PoC
- Send or visit:
http://localhost/login?redirect_url=//ikotaslabs.com - Complete normal login flow.
- After login the app redirects to
https://ikotaslabs.com(orhttp://depending on origin).
Acknowledgements
This vulnerability was discovered using the automated vulnerability analysis tools VulScribe and PwnML. The research and tool development were conducted with support from the MITOU Advanced Program (未踏アドバンスト事業), implemented by the Information-technology Promotion Agency (IPA), Japan.
CWEs
- CWE-601 · URL Redirection to Untrusted Site ('Open Redirect')